Data Brief ; 18: 1740-1749, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29904674

RESUMEN

Six Sigma involves a structured process improvement strategy that places processes on a pathway to continued improvement. The data presented here summarizes a project that took three clinical laboratories from autoverification processes that allowed between about 40% to 60% of tests being auto-verified to more than 90% of tests and samples auto-verified. The project schedule, metrics and targets, a description of the previous system and detailed information on the changes made to achieve greater than 90% auto-verification is presented for this Six Sigma DMAIC (Design, Measure, Analyze, Improve, Control) process improvement project.

2.
Clin Biochem ; 55: 42-48, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29518383

RESUMEN

OBJECTIVE: This study examines effectiveness of a project to enhance an autoverification (AV) system through application of Six Sigma (DMAIC) process improvement strategies. DESIGN AND METHODS: Similar AV systems set up at three sites underwent examination and modification to produce improved systems while monitoring proportions of samples autoverified, the time required for manual review and verification, sample processing time, and examining characteristics of tests not autoverified. This information was used to identify areas for improvement and monitor the impact of changes. RESULTS: Use of reference range based criteria had the greatest impact on the proportion of tests autoverified. To improve AV process, reference range based criteria was replaced with extreme value limits based on a 99.5% test result interval, delta check criteria were broadened, and new specimen consistency rules were implemented. Decision guidance tools were also developed to assist staff using the AV system. The mean proportion of tests and samples autoverified improved from <62% for samples and <80% for tests, to >90% for samples and >95% for tests across all three sites. The new AV system significantly decreased turn-around time and total sample review time (to about a third), however, time spent for manual review of held samples almost tripled. There was no evidence of compromise to the quality of testing process and <1% of samples held for exceeding delta check or extreme limits required corrective action. CONCLUSIONS: The Six Sigma (DMAIC) process improvement methodology was successfully applied to AV systems resulting in an increase in overall test and sample AV by >90%, improved turn-around time, reduced time for manual verification, and with no obvious compromise to quality or error detection.


Asunto(s)
Manejo de Especímenes , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Estándares de Referencia , Manejo de Especímenes/métodos , Manejo de Especímenes/normas
3.
Pract Lab Med ; 2: 29-36, 2015 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-28932802

RESUMEN

OBJECTIVE: To examine the analytical aspects of fecal transferrin (Tf) and hemoglobin (Hb) measured on the NS-Prime analyzer for use in a colon cancer screening program. DESIGNS AND METHODS: Method evaluation and temperature stability studies for fecal Tf and Hb were completed. A method comparison was carried out against the NS-Plus system using samples collected from 254 screening program participants. A further 200 samples were analyzed to help determine suitable reference limits for fecal Tf using these systems. RESULTS: The assay for fecal Tf showed acceptable linearity, precision, and recovery, and showed minimal carryover with low potential for impact by the prozone effect. The 95th percentile for fecal Tf obtained for the reference population was 4.9 µg/g feces. The collection device sufficiently maintained fecal Tf and Hb stability for at least 7 days at room temperature, 4 °C, and -20 °C. Fecal Tf and Hb were most stable at 4 °C and -20 °C, but showed considerable loss (20-40%) of both proteins at 37 °C within the first 7 days. Mixing small amounts of blood into diluted fecal samples maintained at 37 °C for various time periods showed >50% loss of both proteins within 1 h of incubation. CONCLUSIONS: The NS-Prime analyzer showed acceptable performance for fecal Tf and Hb. These studies suggest that use of both Tf and Hb together as biomarkers will result in higher positivity rates, but this may not be attributed to greater stability of Tf over Hb in human feces.